Feuerwehrwissen
Firefighting Knowledge

DIN EN 1028-2 describes the determination of conformity of centrifugal fire pumps with venting devices with the requirements of DIN EN 1028-1, including test methods and conformity assessment. It supplements Part 1 with specific test methods for pumps with a rated flow rate of up to 6000 l/min and aligns with the EC Machinery Directive 2006/42/EC.

Main Content

The standard covers test benches, measurements of flow rate, discharge pressure, and speed, as well as the determination of pump performance curves in diagrams. It requires testing at temperatures ranging from -15 °C to +40 °C and safety inspections for operation and maintenance.

Warranty Points Review

Compliance is verified based on the three guarantee criteria from Part 1:

  • Rated capacity at a suction head of 3 m.

  • 50% at a suction height of 7.5 m.

  • 50% at 1.2 times the pressure and a suction head of 3 m.

Current Version

The current version is DIN EN 1028-2:2008-06 with Corrigendum 1:2009-01, which incorporates Amendment A1:2008 and is cited as a harmonized standard. It replaces DIN EN 1028-2:2002-11 and simplifies the demonstration of conformity.

PPS Pump Test Stands

PPS 4000 Pumpenprüfstand
PPS Pumpenprüfstand
PPS Pumpenprüfstand

Note:
This summary is provided for informational purposes only and does not replace the official standard. No guarantee is made as to its completeness, accuracy, or timeliness. For authoritative information, please consult the current original standard.